Electromagnetic Flowmeter

Carbon Steel
Food and Beverage

It is a flow measurement method based on the electromagnetic field principle. There are 2 coils inside each electromagnetic flowmeter.

Provider

Specifications

Body Material Carbon Steel
DN/NPS/NB(Metric) Min: 0.5 inch ( 15 mm )
Max: 88 inch ( 2200 mm )
Design Standards ISO
Country The Netherlands
Applications Food and Beverage , Mining , Pharmaceuticals , Pulp & Paper , Water Treatment
Pressure Min: 0 Bar ( 0 psi )
Max: 100 Bar ( 1,450 psi )
Protection Classes IP67 , IP68
Temperature Min: -20 C ( -4 F )
Max: 150 C ( 302 F )

Key features/benefits

Electromagnatic Flowmeter is a flow measurement method based on the electromagnetic field principle. There are 2 coils inside each electromagnetic flowmeter. With the help of metal parts placed on these coils, it creates a continuous magnetic field across the cross-sectional area of the measuring tube. The 2 electrodes that sense the voltage are placed inside the measuring tube perpendicular to each other. The insulating material coated on the inner surface prevents the formation of short circuits between the conductive liquid and the metal measuring tube.

In the absence of flow, no electrical tension occurs between the 2 electrodes, the negatively and positively charged ions in the conductive liquid are equal in the liquid. With the initiation of flow, the magnetic field exerts a force on the charged ion particles in the liquid. As a result, the negatively and positively charged ions in the liquid separate from each other and head to opposite sides of the measuring tube. At the end of this situation, an electrical voltage is formed which is sensed by the electrodes.

This voltage is directly proportional to the flow rate in the line. Instant flow can be calculated with the known volume and velocity information of the measuring tube. As the flow rate increases, the separation of the charged particles will increase and the voltage between the electrodes will also increase. The measuring electrodes can also detect magnetic noise in the environment from time to time, this noise signal must be strictly distinguished from the actual measurement signal. To achieve this, the magnetic field must be created with a pulsed direct current.

By constantly changing the places of the charged ions between the electrodes with a direct pulsed current, the effect of magnetic noise is eliminated and precise and stable flow measurement is made. In the simplest way, the Electromagnetic Measurement principle and the Flow rate information are calculated with the above-simplified formula.

In order to provide sensitivity under ideal conditions, the following conditions must be met.

  • The tested liquid must have electrical conductivity.
  • The pipe must be full.
  • The components in the liquid must be homogeneously mixed.
  • If the liquid is magnetically induced, the magnetic field of the device will change and therefore the device needs to be adjusted again.
  • There should be appropriate straight pipe spacing.

Features

MEASURING RANGE 0.05m/s… 15m/s
MEASUREMENT FIELD Conductive Liquids
BODY MATERIAL ST37 Black Steel + Corrosion Resistant Paint
SENSOR MATERIAL SS316L Ops: S5304, Hastelloy C, Hastelloy B, Titanium, Tantalum, Platinum
INNER COATING Teflon (PTFE) or Hard Rubber (Rubber)
PRECISION 0.5% or 0.25% (Türkak Accredited)
TEMPERATURE -10°C … +60°C Rubber / -20°C … + 150°C Teflon
MOISTURE 5%-95%
MEASURABLE MIN. CONDUCTIVITY 20 µs / cm Water 5 µs / cm other Liquid
CONNECTION Flange Connection, Ops: Clamb Connection
PRESSURE PN 6/10/16/25/40/63/100, Class 150/300
PROTECTION CLASS IP67 Compact Type / IP68 Remote Type
FEED 85-265 VAC 50 Hz or 24VDC, Opt. Battery operated
GROUND Grounding Electrode Included
OUTPUT Pulse / Frequency / 4-20Ma / RS485 Modbus / 2 X Transistor Alarm (Programmable) / Opt. HART
INDICATOR 3×16 Backlit LCD Displaying lnstant or Total Flow
ALARMS Empty Pipe, Sensor Error, Over Limit
REPORTING Daily, Weekly, Monthly and Annual total flow (negative / positive / net)
SAMPLING RATE It can be selected from 0.2 to 100 seconds.

Advantages

  • There are no mechanical parts that prevent the flow or reduce the pressure.
  • Measuring scale; 10 times more than other flow meters.
  • All measurements and adjustments can be made/displayed via the integrated or wall-mounted LCD display.
  • It can be composed according to the process and fluid with the user interface. (Density setting can be Inputed.)
  • The menu can be protected with a password.
  • Instant and total flow can be observed on the LCD screen at the same time.
  • With the report feature, old data can be examined. (Daily, weekly, monthly, yearly.)
  • Total flow can only be reset with a password.
  • Flow rates between 0.05 and 15 m/s can be measured and the speed can be monitored on the LCD screen.
  • Calibration (in a fully filled and stable fluid-filled pipe) can be done with the menu.
  • Measurement accuracy can be achieved at 0.2%
  • Conductivity measurements can be made and displayed on the LCD screen.
  • It can take measurements in all homogeneous conductive liquids above 5 uS.
  • It provides resistance to environmental electronic noises through its grounding electrode.
  • Thanks to its flange connection, it provides a reliable, easy and long-lasting assembly feature.
  • Thanks to its metal body, it is protected against external factors.
  • Measurement stability has been significantly increased.
  • Even with low conductivity and high density, the measurement response speed is greatly increased.
  • Electrode material safety has been increased to the highest level.
  • With the DN15-DN2200 production facility, lead times have been minimized.
  • The LCD display resolution has been increased.
  • The product electronics have been revised to make it better, more stable, and more robust.
  • Technical support capacity has been increased and failure support and resolution times have been shortened.
  • With our new calibration facility, TÜRKAK accreditation provides a wide range of services from DN15 to DN2200.

Applications

  • Water and Wastewater lndustry
  • Food and Beverage lndustry
  • Pharmaceutical and Cosmetic lndustry
  • Chemical lndustry
  • Paper lndustry
  • Mining and Energy lndustry
  • Agriculture
  • Machinery Manufacturing lndustry
  • Mining lndustry
  • Energy lndustry
  • Oil lndustry

 

Add 1 more product to start comparing Compare products 0/3